SOP FOR LEAK TEST

  • Home
  • SOP FOR LEAK TEST

SOP FOR LEAK TEST

Objective: To describe the Procedure for Performing a leak test during packing

Scope: This SOP applies to the Production and QA departments.

Responsibility:

  •  Production and IPQA Personnel shall be responsible for Performing the leak test.
  •  Head Quality Assurance shall be responsible for ensuring compliance with SOP.

Procedure:

  • Collect the Tablet strips from the blister Packing machine that cover one complete sealing cycle.
  • Then place the strips in the desiccator of the leak test apparatus filled with water and a few drops of methylene blue indicator.
  • Place the perforated lid over the blisters to prevent floating and then place the lid of the desiccator.
  • Then turn on the vacuum and it takes around 4-5 minutes to build up and release the vacuum.
  • Adjust the vacuum according to the regulatory requirements.
  • Then remove the strips and check for any leakage in the blisters by wiping them off with a free cloth and de-blistering all the strips.
  • If blue color spots or water are present in the pockets and tablets stick to the pockets, then the leak test fails.
  • Inform the QA and Production head if leak tests fail check the sealing temperature and investigate the issue.
  • All the de-foiled tablets should be discarded in the reject bin.
  • Record the observations in the batch record.

Frequency:  shall be performed every  4 hours and IPQA person shall perform in-process once in a shift.